FALCO 300 ENERGY USE
For the FALCO 300 catalytic oxidizer operating at 300 cfm (510 m3/h), energy use is negligible when the inlet concentration is above 800 ppmv gasoline type hydrocarbon. Under these conditions, the heat exchanger recovers enough heat to warm the inlet flow to the minimum entrance temperature (330oC). As the vapor concentration declines from 800 ppmv, the electric heater operates at increasing power levels. The heater load increases progressively with decreasing concentration to a maximum of approximately 14.5 kW at low vapor concentrations (<100 ppm). Assuming $ .10/kWh, the electric power cost increases from less than two cents per hour to about $1.45/hr.
The relationship between power demand and inlet concentration at 300 cfm is illustrated below.
POWER CONSUMPTION VERSUS INPUT CONCENTRATIONS
|
|